- Chef de service
- Neuroradiologie interventionnelle
Signaler une erreur sur cette page
Contacter le service
Neuroradiologie interventionnelle
Secrétariat du chef de service : 03 81 66 85 02
Contributions aux publications scientifiques du CHU Besançon Franche-Comté
Intra-Arterial thrombolysis after SUCCESSful angiographic recanalization in acute large-vessel occlusion stroke of the anterior circulation (IA-SUCCESS): a multicentre, randomised, clinical trial protocol.
Article originalEuropean stroke journal2026-Jul
Auteurs CHU : Di Caterino Fortunato, Charbonnier Guillaume
Intra-arterial thrombolysis (IAT) following successful mechanical thrombectomy (MT) in patients with anterior circulation large-vessel occlusion (LVO) improves cerebral tissue reperfusion and consequently clinical outcome, but has to be validated in non-Asian populations. We hypothesised that IAT with alteplase versus no IAT leads to a better clinical outcome in patients with anterior circulation
Multicentre prospective randomised controlled non-inferiority trial on the efficacy and safety of minimally invasive SAIF vertebral reconstruction technique versus spinal fixation in unstable osteoporotic vertebral compression fractures : a protocol.
Article originalBMJ open2026-Jul
Auteur CHU : Di Caterino Fortunato
Osteoporotic vertebral fractures (OVFs) significantly impact morbidity, mortality, function and quality of life. Stable fractures with controllable pain can be managed conservatively. Those that remain painful can be treated with minimally invasive measures of vertebral augmentation (VA). In contrast, severe and unstable OVFs risk collapse, progressive kyphosis and neurological damage. Conventiona
Right Ventricular Pseudoaneurysm : An Unexpected Complication Following Insertion of Jugular Central Venous Line.
Article originalJACC. Case reports2025-Feb
Auteurs CHU : Kozmek Lada, Vidoni Charles, Besutti Matthieu, Di Caterino Fortunato, Vitale Giovanni, Meneveau Nicolas, Chopard Romain
Right ventricular pseudoaneurysm is a rare and poorly documented condition. This paper reports a case of right ventricular pseudoaneurysm of iatrogenic origin, which developed after placement of internal jugular central venous catheter. The patient underwent successful percutaneous closure. The formation of a pseudoaneurysm is potentially fatal. The main causes are ischemic, postsurgical, infectio
Defining the optimal size of an aspiration catheter in relation to the arterial diameter during mechanical thrombectomy for stroke.
Article originalJournal of neuroradiology = Journal de neuroradiologie2024-Feb
Auteurs CHU : Charbonnier Guillaume, Primikiris Panagiotis, Desmarets Maxime, Tio Gregory, Vancheri Sergio, Di Caterino Fortunato, Vitale Giovanni, Biondi Alessandra
Mechanical thrombectomy for acute ischemic stroke is effective and includes different technical approaches. Operators use direct aspiration, a stent retriever, or a combination of both. Direct aspiration can be performed with various catheters of different sizes depending on the diameter of the occluded vessel. We studied the relationship between the catheter diameter in regards to the occluded ve
Embryology of the vertebral artery and variants of the adult.
Revue de la littératureNeuro-Chirurgie2024-May
Auteur CHU : Di Caterino Fortunato
The vertebral arteries represent in the adult the main blood supply of the posterior cranial fossa, even if they appear relatively late during the embryological life. We reviewed all the most important steps of the vertebral artery's embryological development and the most common variants that can occur in the adult. The aim of this review is to summarize the main events of the development of this
Voir les 2 autres publications
How to use the Contour intrasaccular device : two illustrative cases.
Article originalJournal of neurointerventional surgery2024-Feb
Auteurs CHU : Biondi Alessandra, Primikiris Panagiotis, Di Caterino Fortunato, Vancheri Sergio, Vitale Giovanni, Charbonnier Guillaume
Contour (Stryker, Kalamazoo, MI) is a relatively new endosaccular device for the treatment of intracranial aneurysms.1 2 Its unique cup-like shape permits treatment of most lesions, including wide-necked, irregular, and shallowed-shaped aneurysms. The sizing of the device only requires two parameters: neck size and equatorial plane (width). It must be positioned at the neck of the aneurysm with th
Reply to « Successful recanalization because of the pressure differential between arterial systolic pressure (Push) and vacuum level created by the vacuum source (Pull) ».
LettreJournal of neuroradiology = Journal de neuroradiologie2024-Jun
Auteurs CHU : Charbonnier Guillaume, Di Caterino Fortunato, Biondi Alessandra
